Support

If you have a problem or need to report a bug please email : support@dsprobotics.com

There are 3 sections to this support area:

DOWNLOADS: access to product manuals, support files and drivers

HELP & INFORMATION: tutorials and example files for learning or finding pre-made modules for your projects

USER FORUMS: meet with other users and exchange ideas, you can also get help and assistance here

NEW REGISTRATIONS - please contact us if you wish to register on the forum

Users are reminded of the forum rules they sign up to which prohibits any activity that violates any laws including posting material covered by copyright

trogz tools...

For general discussion related FlowStone

trogz tools...

Postby tester » Sun Sep 22, 2013 2:21 pm

...may require some updates?

Different output vs different reading. Play with input values 0-2.
Attachments
cheating-fix.fsm
(4.62 KiB) Downloaded 941 times
cheating.fsm
(4.58 KiB) Downloaded 828 times
Need to take a break? I have something right for you.
Feel free to donate. Thank you for your contribution.
tester
 
Posts: 1786
Joined: Wed Jan 18, 2012 10:52 pm
Location: Poland, internet

Re: trogz tools...

Postby trogluddite » Sun Sep 22, 2013 6:19 pm

Well spotted! - very strange behaviour, usually it matches exactly with a regular trigger counter, and I can't make sense yet of why an extra S&H makes the difference!
All schematics/modules I post are free for all to use - but a credit is always polite!
Don't stagnate, mutate to create!
User avatar
trogluddite
 
Posts: 1730
Joined: Fri Oct 22, 2010 12:46 am
Location: Yorkshire, UK

Re: trogz tools...

Postby tester » Sun Sep 22, 2013 6:31 pm

I bet that this might have something to do with recent FS updates. Thus - other tools might need to update too.

It partially works in SM, i.e. shows correct values but wrong amount of triggers. I remember there was some change in boolean and/or trigger behaviors between SM and FS3. BTW, why would you not add the S&H on input in your tools by default? Should not the inputs be rather separated from what comes in?
Attachments
partial-works-in-sm.zip
(5.7 KiB) Downloaded 831 times
Need to take a break? I have something right for you.
Feel free to donate. Thank you for your contribution.
tester
 
Posts: 1786
Joined: Wed Jan 18, 2012 10:52 pm
Location: Poland, internet

Re: trogz tools...

Postby MyCo » Sun Sep 22, 2013 8:37 pm

I've isolated the issue. The "Last Switch" primitive somehow blocks duplicated triggers (or maybe it limits the frequency). I've attached a demonstration.

As far as I can remember, this is a new behaviour. Don't think that this is correct.

Edit: Last S|M Version has the same behaviour... so this change was long time ago.
Attachments
duplicate trigger issue (MyCo).fsm
(1.03 KiB) Downloaded 846 times
User avatar
MyCo
 
Posts: 718
Joined: Tue Jul 13, 2010 12:33 pm
Location: Germany

Re: trogz tools...

Postby tester » Sun Sep 22, 2013 9:41 pm

Somehow "switch" behaves logical to me. It reduces... "entangled triggers" :mrgreen:
(a series of triggers associated with 1 value resend?).

But more seriously. If the issue is the same in SM and FS, then why Troggies tool behaves differently in SM and differently in FS?

So it looks, that besides the trigger queue - there might be something else (a marker), that determines triggers as separate "dots" or as a "series". That behavior would explain why adding a timer for "trigger separation" I used in some places - makes the change no mattero how rediculous it sounded.
Need to take a break? I have something right for you.
Feel free to donate. Thank you for your contribution.
tester
 
Posts: 1786
Joined: Wed Jan 18, 2012 10:52 pm
Location: Poland, internet


Return to General

Who is online

Users browsing this forum: No registered users and 54 guests